Large capacity double incubation shaker series加工

Your current position: Home >> Products >> Shakers

Large capacity double incubation shaker series加工

  • Category:Shakers

  • Clicks:
  • Date:2017/12/02
  • More

Product Details Introduction


摇床2012R.jpg

BLBIO-2012


BLBIO-1102/2102

BLBIO-1102/2102

 

  Set incubator and oscillator in one space-saving footprint, less functional and more investment, double the design capacity of more occupies less.
  Housing for high-quality steel plate, stainless steel cavity full mirror assembly, never rust.
  Tilt humane control panel, large screen backlit LCD display, more good visual effect.
  There operational parameter memory function, avoiding the complicated operation and password lock, to prevent human errors.
  There recovery functions, without power interruption affected, the device can automatically restore the original setup program runs.
  With strong rapid cooling systems to achieve instant cooling requirements and has automatic defrost function.
  Large windows with built-in lighting lighting perspective, the entire work status clear glance.
  Machine quiet design, electrostatic spray cabinet, large glass windows can, modeling luxurious appearance.
  Five sections of programmable settings, you can simulate the temperature and velocity curve control. (Custom made)
  Output selectable temperature logger, micro printer or select RS232 interface and PC communications, remote control. (Custom made)
QQ截图20150305151712.jpg

QQ截图20150305151836.jpg

QQ截图20150305151909.jpg

 Large eccentricity cabinet shake-flask characteristics and methods of use
(1)  Due to the eccentricity of this device is greater than the average  distance shaker eccentricity nearly doubled, so it's better operating  characteristics: Because of its large amplitude, both species can be  applied to liquid culture in general, but also for the higher viscosity The seed culture. The results have been very satisfactory.
(2) DO Extra ordinary flask four times - six times.
Use  should be noted: A: When the temperature is not set to complete the  non-press cooling "off button", on the contrary will damage the  refrigeration compressor! !
   
After the completion of the temperature setting by pressing "cooling button"
B: sterilization lights must be turned off in the training process,  this equipment is suitable before training, after the studio to kill  bacteria.
C: speed of use:
              
※ This equipment: 150 r / time: 250 turn quite ordinary shaker / minute.
                        
: 170 r / time: "350 rev / min.
                        
: 200 r / time: "400 rev / min.

D: In the training process if a higher degree of oxygen: You can use the baffle flasks were cultured. This will further increase the dissolved oxygen 6-8 times.
Other operations proceed according to the instructions.
Equipment stainless steel liner. Stainless steel bottle clips. Environment with sterile equipment.
E:  When using 3000 ml -5000 ml bottle speed should not exceed 150 rpm /  min because at this time of volatility, you need to have sufficient  amplitude to reach.

Related Tags:Shakers